top of page

Zavcor Training Academy

Audible Air Leak
Auidible Air Leal

Auidible Air Leal

Play Video

Air Brake System: a) audible air leaks (defect 1.1)/ b) air loss rate exceeds limit
(defect 1.4M)
Audible Air leak
You must know that it’s necessary to check for leaks regularly, and a vehicle has the above Minor Defect
WHEN ANY AIR LEAK CAN BE HEARD.
Must say: “I would notify the operator of the defect.”
“Enter the defect on the Daily Inspection Report.”
“Be allowed to drive the vehicle; and get it fixed as soon as possible.”
Air loss rate exceeds prescribed limit
You must know the proper method for testing the air-loss rate, and that a vehicle has the above Major Defect
WHEN THE AIR PRESSURE DROPS IN ONE MINUTE MORE THAN THE PRESCRIBED LIMIT OF:
• 28 kPa (4psi) is one minute for Class A
• 21 kPa (3psi) is one minute for Class D
Must say: “I would notify the operator of the defect.”
“Enter the defect on the Daily Inspection Report.”
“I would put the vehicle out of service and not drive it.”
PROCEDURE:
• TELL THE EXAMINER, “For any air leaks heard at any time, I would conduct the air-loss rate test.”
• Ensure the vehicle is secured by wheel chocks.
• Release all spring parking/ emergency brakes.
• Ensure the air-system pressure is over 90 PSI. Shut off the engine and turn the key on (if required).
• Hold the brake pedal in the fully applied position and start the timer.
• Observe the air pressure gauges for one minute and note any change. (Disregard the initial pressure drop
and begin test after the pressure has stabilized) and TELL THE EXAMINER.

bottom of page